Q:
How do I clean the head on an ADAT? Resetting Alesis Products? Initialize? ADAT Head Cleaning
A:
ADAT HEAD CLEANING- use a standard VHS DRY cleaner tape (alesis uses Scotch BlackWash brand)...
Note : Dry tape is best saved for emergency "head error" situations during sessions and not reguarded as "maintenance" proceedure. This will sand 8-10 hours of the head away each time it is used. The other parts of the tape path cannot be cleaned correctly with this tape. Recommended maintenance is to "wet clean" heads/tape guides by trained technicians at Alesis service centers at 250 hour intervals. Our "prostart" guide also explains how to lear n this and Alesis does sell a video describing how. -8/2/99,GPB SEE ADAT HIDDEN FUNCTION FILE FOR INITIALIZING AND HEAD HOURS, ETC. Customer service 800 525 3747 use denatured alcohol and special cloth made by TechSpray called "Tech Clean Twillwipe" #2357-100. this can be purchased by them at PO Box 949 Amarillo, TX 79105 806-372-8523 Or at MCM Electronics
Other Popular Articles:
Dimiondions, Specs, software Dimensions Kurzweil K2000 Software Revs Does not start recording until it receives a note! Roland Sound Brush K1000 Misc Reset? Initialize ? Extended Programs etc. Kurzweil 1000 series How do I switch to 220 volts? MTP II Refurbish , Pinout AKG C1000S |