Q:
How come I am not able to hear the Patch that I recorded play back when using an external sequencer on MIDI channel 1?
A:
When the GR-1 is in MONO mode, the BASIC channel and the next 5 channels are used for the current Patch in memory. If you have the BASIC channel set to 1 then you are using channels 1-6 for the Patch. The Parts that are set up in the sequencer section of the GR-1 will override the Patch of the GR-1. Change the BASIC channel of the GR-1 to 11 to alleviate this problem.
Other Popular Articles:
How do I sync the internal sequencer of the GR-1 to an external sequencer? I have the PROTOOLS version of Battery. I cant assign seperate outs other than the Main Left and right.How come? Every time I try to do a data backup to CDR, I get a "disc write error" and/or "track number error". What can I do? Does the MOTU 828 or 896 have an Adat sync port which carries MTC or SMPTE on Windows? What programs can the MOTU 828 and 896 utilize the Adat Sync port on Windows? |