Q:
"Error receiving clock from TDM bus or peripheral" in Digitest.
A:
- Power cycle the system.- Verify that the card order is correct (Disk I/O, Farm, SCII).- Check if the peripheral cable is connected to the Disk I/O.- Check that the TDM ribbon cable is connected/seated properly.- Remove the DigiSetup file from the System Folder and restart. (DigiTest is relying on the DigiSystem INIT to setup the TDM master bit.)- Interface cable plugged in upside down on d24, Disk I/O, or DSP Farm card.- One user reported that switching his 888 back to Internal Sync (he was using a MicroLynx) fixed this.
Other Popular Articles:
Pro Tools crashes on launch. DAE error -9003 when launching Pro Tools. "Could not open 'untitled. image' because it is not the right kind of file" message comes up when trying to open an Image File in MasterList CD. Can't instantiate 2 Mod Delays (short, slap or medium) on 1 DSP chip on a DSP Farm. An Audio Track will not play. There is activity on the meters within Pro Tools, but not on the Audio Interface. |