ADAT Power up while holding PLAY and RECORD. "Drum on" Hrs will not be reset

ADAT-XT Power up while holding PLAY and RECORD. "Drum on" Hrs will not be reset

BRC Power up while holding PLAY and RECORD

AI-2 Power up while holding STORE. (Adat tape header information will also be cleared)

D4 Power up while holding OUTPUT and VOICE.

DM5 Power up while holding OUTPUT and VOICE

HR-16 Power up while holding ERASE, DELETE, and RECORD

HR-16B Power up while holding ERASE, DELETE, and RECORD

Midiverb III Power up while holding INT PROG and STORE

M3 Power up while holding BYPASS and PROG

Midiverb 4 Power up while holding PROG and D

MMT-8 Power up while holding ERASE, PAGE A and PAGE

QS6 Keyboard Power up While holding number ZERO and THREE buttons

Quadrasynth Power up while holding DATA buttons 1 and 4. Note that this only clears the edit

Keyboards buffer. Currently there is no hard reset/re-initialization routine available.

Quadraverb Power up while holding BYPASS and PROGRAM

Quadraverb GT Power up while holding BYPASS and PROGRAM

Quadraverb 2 Power up while holding PROGRAM and COMPARE. This is a soft reset (sets global to default, clears edit buffer but leaves user memory intact).
Power up while holding PROGRAM, COMPARE and >BLOCK. This is a hard reset(set all functions to default and clears user memory).

S4/S8 Sound Power up while holding DATA buttons 1 and 4. Note that this only clears the edit

Modules buffer. Currently there is no hard reset/re-initialization routine available.

SR-16 Power up while holding ERASE and PLAY

X2 Console. Power up while holding ALT, ERASE FWD, and DEC. This is a soft reset Factory mute parameters will be loaded into memory. Currently there is no user hard reset or Re-initialize routine available