Q:
I have an external effects processor that is equipped with digital input and output, but it only supports 44.1kHz or 48kHz sample rates; can I connect it digitally to my 192 I/O for use with an 88.2k, 96k, 176.4k, or 192k session?
A:
This is not possible for the following reason: the Digital Card on the 192 I/O can sample rate convert on input (AES, TDIF, or ADAT on the digital card), but cannot sample rate convert on output (AES, TDIF, or ADAT).
As a workaround, you can go analog out to the effects processor, and return digitally from the effects processor (or just use analog in and out to the effects processor).
Other Popular Articles:
What is the maximum number of 192 I/Os or 96 I/Os I can have attached to my HD system? How many Time Slot does the new TDM II bus on Pro Tools|HD have? Are there any differences in the way those Time Slots are used versus the the way Time Slots are used on a Pro Tools| 24 MIX system? Why do my Patterns not play back correctly when I trigger them from an external sequencer, the Presets are all wrong? Do the Command Stations have groove quantizing? Why do I keep getting stuck notes after I record a new part? |