Q:
How do I initialize the SH-32 - and restore the Factory Settings?
A:
The following procedure can be used to clear the internal memory and reload the
factory settings: (CAUTION: All USER information will be lost. Be sure to back up any information you wish to keep.) 1. Power on the SH-32 while holding 1/A TUNE. 2. Wait for "ALL" to appear in the display. 3. Press WRITE / (EXEC) to display "Sur." 4. Press WRITE / (EXEC) again. 4. When "End" is flashing in the display, power off the SH-32 and power back on normally. |