Q:
I purchased an ACP88 and the only thing that is not clear to me is the +4/-10dBu button on the back. What is the difference between "pro levels" and "line levels"?
A:
+4 and -10 refer to operating levels. +4 is considered "pro" and -10 is often considered consumer level. An operating level indicates what a zero reading on a meter equals. On a VU meter that is on a device set up to operate at -10, a reading of zero on the meter indicates an output level of -10 db. A +4 system at zero on the meter is actually putting out 4 db of signal. In a +4 system, .775 millivolts across 1 watt causes a reading of zero on the meter. This is how the meter is calibrated. If you are using the ACP at the inserts of a channel of a mixer, the usual level is -10. You should check the manual of the device you are using your ACP 88 with to ascertain the o-operating level of the device and adjust the 88, accordingly. If you are unsure, the -10 setting on the 88 outputs and handles lower level signals than the unit would were it set to operate at +4.
Other Popular Articles:
Can I use ASIO drivers with my Event EZBus in Windows? My software application is not recognizing the ASIO driver. How do I know if my EZbus is properly installed in WinXP / WinME? I can't get sound to play back from my computer through the EZbus. I hear a very pronounced echo when I'm recording into my software. I'm using the latest ASIO driver, but it's still not being recognized by my software. |