Q:
Power up sequences
A:
With power off; press and hold the indicated buttons, turn power on, release keys
Drum time PLAY and STOP Fast Wind time FFWD and STOP Syscon Rom STOP, PLAY and REC Servo ver REW, FF and STOP Test Mode FFWD,STOP and PLAY, then, within 2 seconds push STOP Banner Push and hold SHIFT then DOWN ARROW Use UP and DOWN ARROWS to select letters, press SHIFT to save selection. Press UP and DOWN simultaneously to complete procedure. Oscillator SHIFT (LED will blink), UP/DOWN to scroll menu ON = 440 Hz 2 = 1 kHz 3 = 10kHz 4 = White Noise 5 = Ramp Wave Selected signal is sent to REC ENABLED channels and overides inputs. BLOCK ERROR RATE is always available. The VU meters are converted into Error Rate Meters SHIFT then MENU Continue to press MENU untill "bEr off" Press UP arrow or DOWN Arrow to change display to "bEr on". Press SHIFT. Press Play. The meters are configured as follows: 1 Tape Edge (head A) 2 Tape Edge (head B)\ 3 (Not Used) 4 (Not Used) 5 Center of the tape (head A) 6 Center of the tape (head B) 7 (Not Used) 8 (Not Used) Error Quality (number of block error among 128 blocks) Number of lit segements Number of Error Blocks 0 0-7 1 8-15 2 16-23 3 24-31 4 32-39 5 40-47 6 48-55 7 56-63 8 64-71 9 72-79 10 80-87 11 88-95 12 96-128 Change "on" to "off" to disable the Error Rate Meter The Service Manual has a sequence of Test mode error detection. This information is not secret but is of no use to anyone without factory service training. MEP |