Pro Audio Support

Q:
Connecting to the VM-7000 Mixer
 
A:
Note: To connect the VM-7200/7100 and the
ADA-7000 via R-Bus, a VM-24E I/O Expansion Board
(sold separately) must be installed in the VM
processor.
1. With the power off to all devices, connect the
VM-7200/7100 to the ADA-7000 with the R-Bus
cable provided with ADA-7000.
2. Turn the power on the ADA-7000 first, then the
VM-7200/7100 processor. Wait for the
VM-7200/VM-7100 control status to change to
green, then turn on the VM-C7200/C7100
console.
3. Press CLOCK SOURCE on the ADA-7000 to
R-Bus to set the sampling clock.
Set up the VM-7000 as follows:
4. Hold down SHIFT and press PROJECT on the
VM-C7200/C7100 console.
5. Press the DOWN cursor to select the second
row of the SYSTEM MENU.
6. Press F1 [DIGITAL I/O].
7. Press the DOWN cursor to select WORD
CLOCK SOURCE.
8. Use the V1 knob to select INTERNAL.
9. Press F1 [SET] to confirm the setting.