|
|
|
|
|
|
Q:
Connecting to the VM-7000 Mixer
A:
Note: To connect the VM-7200/7100 and the
ADA-7000 via R-Bus, a VM-24E I/O Expansion Board (sold separately) must be installed in the VM processor. 1. With the power off to all devices, connect the VM-7200/7100 to the ADA-7000 with the R-Bus cable provided with ADA-7000. 2. Turn the power on the ADA-7000 first, then the VM-7200/7100 processor. Wait for the VM-7200/VM-7100 control status to change to green, then turn on the VM-C7200/C7100 console. 3. Press CLOCK SOURCE on the ADA-7000 to R-Bus to set the sampling clock. Set up the VM-7000 as follows: 4. Hold down SHIFT and press PROJECT on the VM-C7200/C7100 console. 5. Press the DOWN cursor to select the second row of the SYSTEM MENU. 6. Press F1 [DIGITAL I/O]. 7. Press the DOWN cursor to select WORD CLOCK SOURCE. 8. Use the V1 knob to select INTERNAL. 9. Press F1 [SET] to confirm the setting. |