Q:
Connecting to the VSR-880
A:
Use the following procedure to set-up the VSR-880
for us with the AE-7000: 1. With the power off to all devices, connect the VSR-880 to the AE-7000 with the R-BUS cable. 2. Turn on the AE-7000, then the VSR-880. 3. Press CLOCK SOURCE on the AE-7000 to select R-BUS as the sampling clock. Set up the VSR-880 as follows: 4. Hold down SHIFT and press SYSTEM. i SYS SYSTEM PRM?lM will appear in the display. 5. Press ENT/YES. 6. Use the TIME/VALUE dial to select SYS MasterClk=INT. 7. Press ENT/YES to confirm the setting. 8. Press PLAY/DISPLAY to exit.
Other Popular Articles:
How do I know if I have 24 bit DACs (Digital-Analog Converters)? How do I change the operating level of the 888/24 from +4 to -10? How can I use the 888/24 in Stand Alone mode & How can I tell if it is in Stand Alone mode? Q. How can I increase the polyphony of Unity DS-1 and/or Retro AS-1? Q. What are the recommended Control Panel and memory settings for Unity DS-1? |