Q:
How do I calibrate Digidesign's PRE with my 192I/O?
A:
Here are the correct steps to calibrate the outputs (assuming PT reference is -18dBFS):#1 Make sure that the outputs of your 192 calibrated properly (-18dBFS 1KHz Sine wave=1.228VAC)#2 Connect the +4dBu outputs of the 192 to the Line/Inst inputs of PRE.#3 Change the inputs of PRE to Line-15K and adjust input trims to "06" for each channel#4 In a new session, create 8 mono Aux tracks assigned to separate mono outputs.#5 Instantiate a Signal Generator on one track, 1kHz Sine wave at -18dBFS. Copy the Signal Generator to the other Aux tracks.#6 Adjust the output trims of PRE so that they are 1.228VAC.
Other Popular Articles:
"Error while verifying your authorization. Result Code: 12101" No audio output from Pro Tools when controlling a deck with MachineControl. How to setup more than two headphone mixes with Control|24 or ProControl. How do I get my SampleCell / Soft SampleCell Drum Loop to sustain for as long as I hold down a key on my keyboard? Right now, it is fading out when I hold down a key on my keyboard. Do muted regions export during an OMF export, or are they ignored? |